T1 map from VFA images

Widgets -> T1 -> VFA T1

This widget generates T1 maps from variable flip angle images. This is often used as a preprocessing step for kinetic modelling. The VFA scans can be loaded either as separate volumes, one for each flip angle, or a single multi-volume file containing all the flip angles.

The main VFA method is described in [1].

Using a single 4D volume with multiple flip angles

Click Add to and select the data file containing the VFA images. You will then need to enter the flip angles as a comma separated list which must match the number of volumes in the data set.

_images/t1_multiple_fas.jpg

Once loaded, the file will be added to the list:

screenshots/t1_multiple_fas_loaded.jpg

Loading muliple flip angle volumes

It is also common for the images at different flip angles to be stored in separate files. In this case, simply load each one separately, entering the flip angle for each (the widget will try to guess the flip angle if it is part of the file name, but ensure it has guessed correctly!)

_images/t1_single_fa.png

Using a B1 correction

This option allows for correction of field inhomogeneity and B1 effects using Actual Flip Angle Imaging (AFI) data sets. This is particularly common where high field strengths are used, for example in preclinical applications. The method is described in [2]

These are loaded in the same way as the VFA data described above, however in this case you must enter the TR value for each file in ms (or a sequence of TR values if the AFI data is stored in a single 4D data set).

The flip angle used for the AFI sequence is also required.

screenshots/t1_afi.png

Applying Gaussian smoothing to the T1 map

An optional postprocessing step is to apply smoothing to the output T1 map. The sigma value is standard deviation of the Gaussian used as the smoothing kernel, and is measured in voxels.

The Processing->Smoothing widget can also be used to apply smoothing to the output. This allows the kernel size to be specified in physical units (mm).

Clamping the T1 values

The output T1 values may be clamped between limits if required - this may be useful to eliminate unrealistic values in a small number of voxels.

References

[1]Fram et al., Magn Reson Imaging 5(3): 201-208 (1987)
[2]Yarnykh, V. L. (2007), Actual flip‐angle imaging in the pulsed steady state: A method for rapid three‐dimensional mapping of the transmitted radiofrequency field. Magn. Reson. Med., 57: 192-200. doi:10.1002/mrm.21120